1756-OB16E PDF

Rockwell Automation Publication TDJ-EN-P – November ControlLogix I/O Specifications. OB16E. ControlLogix DC (10 V ). OB16E Low Price Guarantee! Allen Bradley – Rockwell Automation ControlLogix. ALBOB16E New, Repair and Reman Parts. Ships Fast and 2 YR. Get OB16E CONTROLLOGIX 16 POINT D/O MOD at wholesale prices at Westburne – your electrical distributor. Join Now!.

Author: Tutaxe Tobei
Country: Thailand
Language: English (Spanish)
Genre: Sex
Published (Last): 19 March 2012
Pages: 236
PDF File Size: 12.8 Mb
ePub File Size: 11.97 Mb
ISBN: 991-6-35403-655-5
Downloads: 92307
Price: Free* [*Free Regsitration Required]
Uploader: Dugar

This is provided as an example only of how I would reset the fuse from logic!! Once you right-click the module, go to Properties.

OB16E – In Stock | Allen Bradley PLC ControlLogix

Note that it is necessary that the chassis and power supply be installed and grounded before installing this module with the RTB.

Be sure to read up on the dangers, and proper procedures for resetting the fuse this way. Leave a comment Cancel reply Your email address will not be published.

The first fuse protects outputs 0 to 7. Power dissipation of this module has a maximum of 4. In this case, my output module is in slot 6 of the local chassis.

Sold by toronjaparty New seller Contact 1576-ob16e. On the other hand, chances are 1756-ob16f one fuse bank needs to be reset. In your own logic, you will probably not want to allow the operator to reset the fuse unless the fuse is blown in the first place.

The controller can offer a scalable controller design that can provide many settings that work for different applications and accessories. A power cycle to the chassis will reset the fuses.

OB16E | Allen Bradley PLC – Rockwell Automation ControlLogix | ALBOB16E

In summary, he OB16E has two electronic fuses. If you reset a fuse that is not blown, the outputs will be temporarily shut off, then re-energized.

TOP Related  DISCOVER ENGLISH ROD BOLITHO BRIAN TOMLINSON PDF

For this reason, we must know the procedure for resetting fuses in the even that an overload condition takes place.

If you are online with the processor, you can right click the OB16E in the Controller Organizer window. Any Condition Any Condition. The lowest-priced brand-new, unused, unopened, undamaged item in its original packaging where packaging is applicable. This module has been routine tested at V AC for 2 s and has a continuous isolation voltage of V. The wiring is located underneath the module as well, and this can make coordinating connections easy to do and also allows for maximum output for your system.

The rack and controller systems can offer multiple accessories for your computer. One one hand, this would be less severe than cycling power to the entire chassis.

Please contact us for additional information about our repair process. This item doesn’t belong on 175-6ob16e page. If you reset the fuse, some outputs will likely energize right away. Pulling the module will cause power loss to all outputs 1756-b16e the module not just the bank that is blown. On the diagnostic tab, you can reset the blown fuse bank. The problem with this, however is that we must shut the entire system down.

Be the first to write a review. Resetting the fuse while your equipment is running could cause unexpected operation. Its operating temperature is between 0 and 60 Degrees Celsius and its non-operating temperature is between and 85 Degrees Celsius.

Resetting Fuses (1756-OB16E)

We have ratings, but no written reviews for this, yet. This module also allows modification of the states in Fault mode and the states in Program mode. If you are unfamiliar with the message instruction, 1756ob16e read up on it here. Its total backplane power is 1.

TOP Related  NITIN UPADHYAY DESIGN AND ANALYSIS OF ALGORITHM PDF

Using the RSLogix programming software, it is possible to configure the OB16E module’s transition from Program state to Fault state, the output state in Fault mode, or the output state in program mode.

All our repairs come with a 1 Year Warranty. There are several ways to reset the fuses. See details for additional description.

Allen-Bradley 1756-OB16E/A Output Module

The OB16E module is an electronically fused output module. The module also has an operating voltage range from 10 to We can perform a power cycle, we can reset the fuses from the properties of the module, or we can execute a message instruction to reset the fuses. The second fuse protects outputs See all 2 brand new listings. Another way to reset the fuse is with a message instruction. Its minimum load current is 3 milliamps 1756-kb16e point and 1756-ob16f typical surge current is 2 A for 10 s per point, which is repeatable every 2 s at 0 Degree Celsius.

Skip to main content. Another option is to remove the OB16E from the chassis, and reseat the module. Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. It 1756–ob16e also able to work with third party devices in addition to ControlLogix.